bingo: planned status and capacity type
All checks were successful
Build and Deploy to Production / test (push) Successful in 23s
Build and Deploy to Production / build (push) Successful in 1m0s
Build and Deploy to Production / deploy (push) Successful in 39s

"MW" on the card mixed IT load, connected power, total site power,
design capacity and even MVA (Oxygen, Sber Yuzhny Port). Record which
one a figure is in a new mw_type column; the dialog tags the number
("64 MW · design") and MVA replaces the unit, while cells keep the bare
figure to stay readable. Add a "planned" status for projects not yet
under construction; like "building", it is left out of the operational
view.

Assisted-by: Claude:opus-5
This commit is contained in:
Sergei Poljanski 2026-10-10 06:59:04 +04:00
commit e5bd1c1ac7
Signed by: asxpi
GPG key ID: 4F8851660FA4121B
9 changed files with 69 additions and 9 deletions

View file

@ -0,0 +1,7 @@
Sequel.migration do
change do
# What the mw figure measures: it | connected | total | design | mva.
# NULL = not stated by the source.
add_column :bingo_datacenters, :mw_type, String
end
end